Flare Tip Lining-Rammed

 
 
 
Thermbond Refractories
 
 
 
APPLICATION REPORT
 
Flare Tip Lining- Rammed
 
 
Industry: Petrochemical
 
Description of Equipment: Two fabricated replacement sections of flare tip.
 
Problem: Flare tips must be lined with refractory to prevent metal erosion. There is no way to heat-cure conventional refractory for this application once the sections are erected.
 
Solution: Full-thickness Thermbond Refractory lining installed on SS-310 1" thick hex-mesh. Thermbond does not require a heat-cure thus solving the problem.
 
Internal view of partially completed
flare tip.
Flare tip installation full thickness in
two uppermost sections.
Finished installation of Thermbond
material in new flare tip top section.
 
Product Being Replaced: Resco AA-22
 
Products Applied: Thermbond Formula 12-L
 
Method of Installation: Rammed
 
Equipment Used: Hobart Mixer, Pneumatic Ramming Hammer, miscellaneous tools
 
Scope of Work: Rammed full thickness of Formula 12-L into 1" SS-310 hex-mesh anchorage on internal surface of two top sections of the fare stack.
 
Installation Date: April 2006
 
Follow Up: January 2007 inspection. Unit is fully operational. No failure detected.
 